What was found
CRACK CORRUGATED PLATE TRAILING EDGE ORSS 261 RT WING. REPLACED CORRUGATED PLATE AND FASTENERS LOCATED ORSS 261 AT RT WING IAW SRM 51-40-02, & DWG 115A2714, SHEET 6, REV -. LENGTH OF CRACK IS 0.750 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK CORRUGATED PLATE TRAILING EDGE ORSS 261 RT WING. REPLACED CORRUGATED PLATE AND FASTENERS LOCATED ORSS 261 AT RT WING IAW SRM 51-40-02, & DWG 115A2714, SHEET 6, REV -. LENGTH OF CRACK IS 0.750 INCH.