As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHILE INWORK INSTALLING RH VAPOR BARRIER FOUND SUPPORTING DOUBLER IS CRACKED<[01] FABRICATED ON RH VAPOR BARRIER SUPPORTING DOUBLER FROM 2024T3#0.040 C LOT#1614857-1 IAW SRM 51-40-05 AND DWG 111A1511 ID: 0025 REV: - <BR>MATERIAL REPLACEMENT; MATERIAL 2024 T42 BY 2024T3 PER SRM 51-30-01-0G-0 STEP 8 FLAT PATTERNS TABLE A TABLE C;[02] VERIFIED CORRECTIVE ACTION #1