What was found
CORROSION INTERCOSTAL FLOOR STRUCTURE LOCATED BTW STA 947 TO STA 967 RBL 50 WL 208.1 AT AFT GALLEY AREA. REPLACED NEW INTERCOSTAL FLOOR STRUCTURE AND FASTENERS LOCATED BTW STA 947 TO STA 967 RBL 50 WL 208.1 AT AFT GALLEY AREA. IAW SRM 51-40-02 SRM 51-10-02 ITEM 9 AND DWG:147A5650; SHEET 71; REV A.