What was found
CRACK TRAILING EDGE SUPPORT ANGLE LOCATED INTERNAL CAVITY AT LEVEL ORSS 285 AT LT WING. REPLACED TRAILING EDGE SUPPORT ANGLE LOCATED INTERNAL CAVITY AT LEVEL ORSS 285 AT LT WING IAW SRM 51-40-02, SRM 51-10-02 ITEM 9, AND DWG 115A6200, SHEET 10, REV-. MEASUREMENT OF CRACK IS L: 0.0373'.