What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED STA695 AND LBL24.75 PASSENGER CABIN. REPLACED SUPPORT ANGLE AND FASTENERS LOCATED ON FLOOR STRUCTURE IAW SRM 51-40-02-0G-0, & DWG 273A9111, SHEET 6, REV A, AND DWG 111A6000, SHEET 178, REV-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ANGLE FLOOR STRUCTURE LOCATED STA695 AND LBL24.75 PASSENGER CABIN. REPLACED SUPPORT ANGLE AND FASTENERS LOCATED ON FLOOR STRUCTURE IAW SRM 51-40-02-0G-0, & DWG 273A9111, SHEET 6, REV A, AND DWG 111A6000, SHEET 178, REV-.