CRACK ANGLE FLOOR STRUCTURE LOCATED STA695 AND RBL24.75 PASSENGER CABIN. REPLACED SUPPORT ANGLE AND FASTENERS LOCATED ON FLOOR STRUCTURE AT STA695 AND RBL24.75 PASSENGER CABIN IAW SRM 51-40-02-0G-0, DWG 273A9111, SHEET 6, REV A, AND DWG 111A6000, SHEET 178, REV-.