What was found
AFTER START OF NR 2 ENG; SOURCE OFF LIGHT ILLUMINATED AND FUEL FLOW WENT TO ZERO, HAD WHITE FLASHING BOX AROUND EGT, AND SHUT NR 2 ENG DOWN. C/W EEC BITE IAW FIM 73-00 TASK 801. NO FAULTS FOUND FOR NR 2 ENG. C/W ENG IDLE RUN WITH CREW IAW AMM 71-00-00 RAN ENG FOR 5 MINS ENG RUN SUCCESSFUL WITH NO FAULTS NOTED. ACFT OK FOR SERVICE. WORK ORDER 107675. C/W EEC BITE IAW FIM 73-00 TASK 801. NO FAULTS FOUND FOR NR 2 ENG. C/W ENG IDLE RUN WITH CREW IAW AMM 71-00-00 ; RAN ENG FOR 5 MINS; ENG RUN SUCCESSFUL WITH NO FAULTS NOTED. ACFT OK FOR SERVICE.