What was found
CRACK INDICATION ON HORIZONTAL PRESSURE DECK WEB LBL 31 STA 663. CRACK LENGTH: 0.200 IN. PERFORMED REPAIR ON THE PRESSURE DECK IAW SRM 53-40-51-2R-2, REPAIR 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK INDICATION ON HORIZONTAL PRESSURE DECK WEB LBL 31 STA 663. CRACK LENGTH: 0.200 IN. PERFORMED REPAIR ON THE PRESSURE DECK IAW SRM 53-40-51-2R-2, REPAIR 2.