What was found
CRACK ANGLE LOCATED BS 867, LBL 10 IN THE AFT CARGO COMPARTMENT. REPLACED ANGLE LOCATED BS 867, LBL 10 IAW SRM 51-10-02, ITEM 9, AND INSTALLED FASTENERS IAW SRM 51-40-02, AND DRAWING 149A8102, SHEET 17, REV-. MEASUREMENT OF CRACK IS 0.550 INCH.