What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS 344 TO BS 360 AND LBL 12 FWD GALLEY AND LAV. REPLACED THE FLOOR SUPPORT IAW SRM 51-10-02-0G-0 ITEM 9; SRM 51-40-02-0G-0 AND DWG: 141A5400 SHEET: 46 REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS 344 TO BS 360 AND LBL 12 FWD GALLEY AND LAV. REPLACED THE FLOOR SUPPORT IAW SRM 51-10-02-0G-0 ITEM 9; SRM 51-40-02-0G-0 AND DWG: 141A5400 SHEET: 46 REV A.