What was found
CRACK FLOOR SUPPORT BTW BS 277 TO 294.5, BL 0. REPLACED THE FLOOR SUPPORT IAW SRM 51-10-02, ITEM 9, AND SRM 51-40-02. MEASUREMENT OF THE CRACK IS 1.0675 INCHES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK FLOOR SUPPORT BTW BS 277 TO 294.5, BL 0. REPLACED THE FLOOR SUPPORT IAW SRM 51-10-02, ITEM 9, AND SRM 51-40-02. MEASUREMENT OF THE CRACK IS 1.0675 INCHES.