What was found
CRACKED GUSSET ANGLE, BS 500I, STRINGER 19R IN THE FWD CARGO BAY. MEASUREMENT OF THE CRACK IS L: 0.9235 INCHES. . REPLACED GUSSET ANGLE IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, AND DWG: 143A7902, SHEETS 256 AND 257, REV B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED GUSSET ANGLE, BS 500I, STRINGER 19R IN THE FWD CARGO BAY. MEASUREMENT OF THE CRACK IS L: 0.9235 INCHES. . REPLACED GUSSET ANGLE IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, AND DWG: 143A7902, SHEETS 256 AND 257, REV B.