What was found
CRACK ON THE ANGLE LOCATED AFT FACE BS 500H, STRINGER 26L IN THE FWD CARGO BAY. REPLACED THE ANGLE IAW SRM 51-10-02, ITEP 9, SRM 51-40-02, AND DWG 143A7505, SHEET 139, REV-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON THE ANGLE LOCATED AFT FACE BS 500H, STRINGER 26L IN THE FWD CARGO BAY. REPLACED THE ANGLE IAW SRM 51-10-02, ITEP 9, SRM 51-40-02, AND DWG 143A7505, SHEET 139, REV-.