What was found
CRACK ON THE FLOORBEAM, BS 540 BTW BL 0 TO RBL 24.75, WL 208.1. REPLACED THE FLOORBEAM IAW SRM 51-40-02-0G-0, SRM 51-10-02-0G-0, ITEM 9, & DWG 143A0060, SHEET 64, REV-. MEASUREMENT OF CRACK IS 0.380.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON THE FLOORBEAM, BS 540 BTW BL 0 TO RBL 24.75, WL 208.1. REPLACED THE FLOORBEAM IAW SRM 51-40-02-0G-0, SRM 51-10-02-0G-0, ITEM 9, & DWG 143A0060, SHEET 64, REV-. MEASUREMENT OF CRACK IS 0.380.