What was found
MID CABIN FLOOR EXPANSION JOINT AT BS 540 CRACKED AT FASTENER LOCATION NEAR RBL 1. REMOVED AND REPLACED THE FLOORBEAM ASSY IAW SRM 51-40-02-0G-0, 51-40-05-0G-0, AND DWG 143A0060, SHEET 64, REV- APPLIED CIC IAW AMM 51-21-91-620-802.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MID CABIN FLOOR EXPANSION JOINT AT BS 540 CRACKED AT FASTENER LOCATION NEAR RBL 1. REMOVED AND REPLACED THE FLOORBEAM ASSY IAW SRM 51-40-02-0G-0, 51-40-05-0G-0, AND DWG 143A0060, SHEET 64, REV- APPLIED CIC IAW AMM 51-21-91-620-802.