What was found
LOSS OF A HYDRAULICS, QUANTITY ZERO. R & R SYSTEM A ED PUMP IAW AMM 29-11-21-000 IAW SUB TASK 729-PRD-01-01. REMOVED & REPLACED THE NR 1 OTBD GROUND SPOILER ACTUATOR OPS AND LEAK CHECK GOOD IAW AMM 27-62-94. LEAK CHECKED EMDP AND EDP HYDRAULIC PUMPS AND FILTERS, NO FAULTS NOTED IAW AMM 29-11-11, 71-00-00 AND AMM 29-11-21.