What was found
CRACK INDICATION ON STUB FRAME, BETWEEN BS 294.5 - 296.5, S8R - 9R AT THE FWD GALLEY DOOR AREA. CRACK LENGTH: 1.187 IN. REPLACED THE STUB FRAME IAW SRM 51-40-02-0G-0, AND DWG 141A8370, SHEET 10, REV D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK INDICATION ON STUB FRAME, BETWEEN BS 294.5 - 296.5, S8R - 9R AT THE FWD GALLEY DOOR AREA. CRACK LENGTH: 1.187 IN. REPLACED THE STUB FRAME IAW SRM 51-40-02-0G-0, AND DWG 141A8370, SHEET 10, REV D.