What was found
CRACKED FLOOR SUPPORT BTW BS 344 - 360, BL 0, IN THE FWD GALLEY AND LAV. REPLACED THE FLOOR SUPPORT AND FASTENERS IAW SRM 51-40-02, AND DWG 141A5400, SHEET 32, REV-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED FLOOR SUPPORT BTW BS 344 - 360, BL 0, IN THE FWD GALLEY AND LAV. REPLACED THE FLOOR SUPPORT AND FASTENERS IAW SRM 51-40-02, AND DWG 141A5400, SHEET 32, REV-.