What was found
MAIN CABIN, FWD WET AREA FLOOR SUPPORT CRACKED, BTW BS 312 - 328, RBL 27. REPLACED THE FLOOR SUPPORT AND FASTENERS IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, AND DWG 141A5400, SHEET 39, REV-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN, FWD WET AREA FLOOR SUPPORT CRACKED, BTW BS 312 - 328, RBL 27. REPLACED THE FLOOR SUPPORT AND FASTENERS IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, AND DWG 141A5400, SHEET 39, REV-.