What was found
CRACKED SUPPORT ANGLE FLOOR STRUCTURE, BS 695, AND RBL 24.5. REPLACED THE SUPPORT ANGLE AND FASTENERS IAW SRM 51-40-02-0G-0, & DWG 273A9110, SHEET 6, REV A, & DWG 111A6000, SHEET 178, REV-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED SUPPORT ANGLE FLOOR STRUCTURE, BS 695, AND RBL 24.5. REPLACED THE SUPPORT ANGLE AND FASTENERS IAW SRM 51-40-02-0G-0, & DWG 273A9110, SHEET 6, REV A, & DWG 111A6000, SHEET 178, REV-.