What was found
CRACK ON TIE CLIP LOCATED BS 277 AT LEVEL STR 10R AT FWD GALLEY AREA. REPLACED THE TIE CLIP IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, DWG 141A1110, SHEET 17, REV -, AND DWG 141A8380, SHEET 20, REV -.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.