CRACK CORRUGATED PLATE TRAILING EDGE ORSS 297 AT RT WING. REPLACED CORRUGATED PLATE TRAILING EDGE ORSS 297 AT RT WING IAW SRM 51-40-02-0G-0, AND DWG 115A3700, SHEET 82, REV A, AND APPLIED PROTECTIVE TREATMENT ON AREA IAW SRM 51-20-01-0G-0.