What was found
CRACK ON SUPPORT ANGLE LOCATED AT BS 294.5, STRINGER 13L IN FWD GALLEY AREA. REPLACED SUPPORT ANGLE AND FASTENERS BS 294.5, STRINGER 13L IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, & DWG 141A1311, SHEET 1, REV C.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON SUPPORT ANGLE LOCATED AT BS 294.5, STRINGER 13L IN FWD GALLEY AREA. REPLACED SUPPORT ANGLE AND FASTENERS BS 294.5, STRINGER 13L IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, & DWG 141A1311, SHEET 1, REV C.