What was found
CORROSION GROUND PLATE LOCATED BTW HINGE 7A TO HINGE 8 AT VERTICAL STABILIZER. REPLACED BRACKET PLATE LOCATED BTW HINGE 7A TO HINGE 8 AT VERTICAL STAB IAW SRM 51-10-02 PARAGRAPH 9, SRM 51-40-02, AND DWG 175A1601, SHEET 18, REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION GROUND PLATE LOCATED BTW HINGE 7A TO HINGE 8 AT VERTICAL STABILIZER. REPLACED BRACKET PLATE LOCATED BTW HINGE 7A TO HINGE 8 AT VERTICAL STAB IAW SRM 51-10-02 PARAGRAPH 9, SRM 51-40-02, AND DWG 175A1601, SHEET 18, REV A.