What was found
FCD SURROUND STRUCTURE; SUB THRESHOLD BS 440 TO 490, RBL 22, WL 156 HAS SEVERAL SPOTS OF CORROSION. REMOVED AND REPLACED SUB THRESHOLD WEB IAW SRM 51-40-02-0G-0 AND DWG 143A8330 REV G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FCD SURROUND STRUCTURE; SUB THRESHOLD BS 440 TO 490, RBL 22, WL 156 HAS SEVERAL SPOTS OF CORROSION. REMOVED AND REPLACED SUB THRESHOLD WEB IAW SRM 51-40-02-0G-0 AND DWG 143A8330 REV G.