What was found
FWD VERTICAL STIFFENER BUCKLED ON STAB RIB AT STA 295.1; RIB MPN 182A5605-4. C/W NDT INSPECTION OF RIB PRIOR TO REWORK PER NDT PART 6 51.00.00 PROCEDURE 23. NO DEFECTS NOTED AT TIME OF INSPECTION. C/W NDT INSPECTION OF RIB AFTER REWORK PER NDT PART 6 51.00.00, PROCEDURE 23. NO DEFECTS NOTED. PERFORMED A DYE PENETRANT INSPECTION IAW SOPM 20-20-02 OF RADIUS OF THE PN 182A5605-3 STIFFENERS AND CHORDS; COMMON TO REFORMED AREA, AND 2 INCHES UPPER AND DOWN OF REFORMED AREA, TO ENSURE NO CRACKS OR OTHER DAMAGES EXIST. NO DEFECTS NOTED. REPAIR ACCOMPLISHED IAW EA 26-155-00044-WIP1. REPAIR ACCOMPLISHED IAW EA 26-155-00044-WIP1 & WIP 2 (COMPONENT - SWA - REPAIR - HORIZONTAL STABILIZER (RH) INSPAR RIBS DAMAGED) REF. TTG8Q019R798.