What was found
FWD VERTICAL STIFFENER BUCKLED ON STAB RIB AT STA 304.5; RIB MPN 182A5701-4. C/W NDT INSPECTION OF RIB PRIOR TO REWORK PER NDT PART 6 51.00.00 PROCEDURE 23. NO DEFECTS NOTED AT TIME OF INSPECTION. C/W NDT INSPECTION OF RIB AFTER REWORK PER NDT PART 6 51.00.00 PROCEDURE 23. NO DEFECTS NOTED AT TIME OF INSPECTION. REPAIR ACCOMPLISHED IAW EA 26-155-00044-WIP1.