What was found
EMERGENCY EXIT LIGHTS ILLUMINATED THE EMERGENCY EXIT LIGHTS IN THE CABIN ILLUMINATED WITHOUT A LOSS OF AIRCRAFT POWER. THIS EVENT WAS ACCOMPANIED SIMULTANEOUSLY WITH AN ODOR IN THE COCKPIT & FORWARD GALLEY. AFTERWARDS ONLY SOME OF THE EMERGENCY EXIT LIGHTS REMAINED ILLUMINATED. CYCLED LIGHTING EMERGENCY CHARGER, FWD (P18-3; A11) CIRCUIT BREAKER IAW AMM 33-51-00. EMERGENCY EXIT LIGHTS OPERATE NORMALLY. PERFORMED SMOKE OR FUMES IN CABIN CONDITIONAL INSPECTION IAW AMM 05-51-56. NO FAULTS FOUND AND ODOR HAS DISSIPATED.