What was found
CRACKED ANGLE LOCATED FLOOR STRUCTURE BS 500I AT STR28R IN FWD CARGO BAY. REPLACED THE ANGLE IAW SRM 51-10-02, ITEM 9, SRM 51-40-05, SRM 51-20-01, DWG 143A7902, SHEET 320, REV -.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED ANGLE LOCATED FLOOR STRUCTURE BS 500I AT STR28R IN FWD CARGO BAY. REPLACED THE ANGLE IAW SRM 51-10-02, ITEM 9, SRM 51-40-05, SRM 51-20-01, DWG 143A7902, SHEET 320, REV -.