What was found
CRACK INDICATION FOUND ON THE LT HORIZONTAL STAB LOWER SKIN PANEL HSS 193.9 RIB & 16 INCHES FROM FRONT SPAR, INBD SIDE OF RIB. CRACK LENGTH: 0.900 INCH. REPAIRED HORIZONTAL STAB LOWER SKIN IAW SRM 51-40-02, SRM 55-10-01-2R-11, REPAIR 11.