What was found
EMERGENCY EXIT SIGN MOUNTED ON AFT WALL OF FORWARD LAVATORY HAS ONE BULB THAT DOES NOT ILLUMINATE. REMOVED & REPLACED BLOWN LAMP FOR EMERGENCY EXIT SIGN & PERFORMED GOOD OPS TESTED IAW AMM 33-51-01-960-801.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY EXIT SIGN MOUNTED ON AFT WALL OF FORWARD LAVATORY HAS ONE BULB THAT DOES NOT ILLUMINATE. REMOVED & REPLACED BLOWN LAMP FOR EMERGENCY EXIT SIGN & PERFORMED GOOD OPS TESTED IAW AMM 33-51-01-960-801.