As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ELECTRICAL GROUND POWER RECEPTACLE SURROUND DOUBLER CRACKED WITH MATERIAL MISSING ON LOWER EDGE. PERFORMED HFEC INSPECTION OF DAMAGE REMOVAL AND INTERIOR STRUCTURE IAW NDT PART 6 51-00-00, FIG.23. NO DEFECTS NOTED. REPAIRED ELECTRICAL GROUND POWER RECEPTACLE SURROUND DOUBLER LOWER EDGE IAW SRM 53-10-15-2R-4-B00449, REPAIR 4.