What was found
CRACKED FLOOR SUPPORT BS 380 - 400, RBL 8, WL 208. REMOVED, LOCATED, DRILLED AND INSTALLED NEW FLOOR SUPPORT IAW SRM 51-40-02, AND DWG 143A5400, REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED FLOOR SUPPORT BS 380 - 400, RBL 8, WL 208. REMOVED, LOCATED, DRILLED AND INSTALLED NEW FLOOR SUPPORT IAW SRM 51-40-02, AND DWG 143A5400, REV A.