What was found
CRACKED STRINGER CLIP, BS 727C, S7L. ACCOMPLISHED HFEC SURFACE SCAN OF STRINGER CLIP AREA IAW NDTM, PART 6, CHAPTER 51-00-00, PROCEDURE 23. VERIFIED CRACKED. REMOVED BS 727C; S-7L STRINGER CLIP PER SRM 51-40-02. LOCATED AND DRILLED NEW STRINGER CLIP PER SRM 51-40. FABRICATED NEW STRINGER CLIP IAW SRM 51-30-01, AND DWG 143A1010-1, REV C. TREATED, & APPLIED CHEMICAL CONVERSION COATING & PRIMED IAW AMM 51-21-41-370-802, & AMM 51-21-72-370-804. INSTALLED THE NEW STRINGER CLIP IAW SRM 51-40-02, DWG 146A1103 REV 05, AND DWG 146A1103, REV-.