What was found
CRACK ON TIE CLIP FLOOR STRUCTURE LOCATED BETWEEN BS500I AND STR26R AT FWD CARGO COMPARTMENT 2026-93269<[01] REPLACED TIE CLIP FLOOR STRUCTURE LOCATED BETWEEN BS500I AND STR26R AT FWD CARGO COMPARTMENT IAW B737-800 SRM 51-40-02-0G-0 AND DWG 143A1234 SHEET: 14 REV: A;[02] CORRECTED STEP 1: REPLACED TIE CLIP FLOOR STRUCTURE LOCATED BETWEEN BS500I AND STR26R AT FWD CARGO COMPARTMENT IAW B737-800 SRM 51-40-02-0G-0 AND DWG 143A1234 SHEET: 14 REV: A SEE INDIVIDUALS SIGN OFF BELOW;[03] REPLACED TIE CLIP FLOOR STRUCTURE LOCATED BETWEEN BS500I AND STR26R AT FWD CARGO COMPARTMENT IAW B737-800 SRM 51-40-02-0G-0 AND DWG 143A1234 SHEET: 14 REV: A SEE INDIVIDUALS SIGN OFF BELOW