What was found
CRACKED GUSSET ANGLE LOCATED BS 500I AT LEVEL STR 21L IN THE FWD CARGO COMPARTMENT. REPLACED THE GUSSET ANGLE AND FASTENERS LOCATED IAW SRM 51-40-02, AND DWG 143A7902, SHEET 256, REV B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED GUSSET ANGLE LOCATED BS 500I AT LEVEL STR 21L IN THE FWD CARGO COMPARTMENT. REPLACED THE GUSSET ANGLE AND FASTENERS LOCATED IAW SRM 51-40-02, AND DWG 143A7902, SHEET 256, REV B.