What was found
CRACK ON SUPPORT ANGLE LOCATED BTW BS 291.5 TO BS 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA. REPLACED SUPPORT ANGLE LOCATED BTW BS 291.5 TO BS 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA; IAW SRM 51-40-02 AND DWG 141A8310, SHEET 33, REV-.