What was found
CRACKED ANGLE, BS 500C, STRINGER 26L. REPLACED THE ANGLE, & FASTENERS IAW SRM 51-40-02, & DWG 143A7505, SHEET 84, REV -.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED ANGLE, BS 500C, STRINGER 26L. REPLACED THE ANGLE, & FASTENERS IAW SRM 51-40-02, & DWG 143A7505, SHEET 84, REV -.