What was found
CRACK WEB ON CEILING INTERNAL STRUCTURE, BS 847 - 867, LBL 21. REPLACED THE WEB IAW SRM 51-10-02, ITEM 9, & DWG 149A8100, SHEET 1, REV-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK WEB ON CEILING INTERNAL STRUCTURE, BS 847 - 867, LBL 21. REPLACED THE WEB IAW SRM 51-10-02, ITEM 9, & DWG 149A8100, SHEET 1, REV-.