What was found
CRACKED FLOOR WEB BTW BS 312 TO BS 328 AT LBL 46. REPLACED FLOOR WEB BTW BS 312 TO BS 328 AT LBL 46 AT FWD GALLEY AREA IAW SRM 51-40-02 AND DWG 141A5400 SHEET 39 REV. -.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED FLOOR WEB BTW BS 312 TO BS 328 AT LBL 46. REPLACED FLOOR WEB BTW BS 312 TO BS 328 AT LBL 46 AT FWD GALLEY AREA IAW SRM 51-40-02 AND DWG 141A5400 SHEET 39 REV. -.