What was found
ONE AFT FLASHLIGHT WILL NOT TEST. OK TO CONTINUE PER MEL 25-64-02A SP1B. CLEANED CONTACTS ON FLASHLIGHT BASE RESEATED FLASHLIGHT APPLIED NEW SEAL FLASHLIGHT OPERATIONAL CHECK IS GOOD IAW AMM 25-64-00-200-801-MAX-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ONE AFT FLASHLIGHT WILL NOT TEST. OK TO CONTINUE PER MEL 25-64-02A SP1B. CLEANED CONTACTS ON FLASHLIGHT BASE RESEATED FLASHLIGHT APPLIED NEW SEAL FLASHLIGHT OPERATIONAL CHECK IS GOOD IAW AMM 25-64-00-200-801-MAX-01.