What was found
NUMBER 2 ENG FAILED ON TAKEOFF; REJECT AT APPROX 100 KIAS BRK ENERGY 21.1M FT-LB. INSPECTION REQUIRED ABOVE 30.0M FT-LM. DURING INITIAL EVALUTATION FAULT CODE 73-31552 IS PRESENT IN EEC IAW FIM 73-31, TASK 803. PERFORMED GVI OF NR 2 ENGINE AND DISCOVERED HMU LEAKING FUEL. ACCOMPLISHED AN INSPECTION OF THE NR 2 ENGINE CHIP DETECTORS AND FOUND NO MAGNETIC PARTICLES REF. AMM 79-00-00. R & R FUEL PUMP IAW TASK CARD REF TTG8Q01BW3Y. R & R HMU IAW AMM 73-21-10. REQUIRES TEST 15 - 85% N1 LEAK CHECK PER POWERPLANT TEST REF TABLE 71-00-00. INSPECTED AND VERIFIED THE WORK PERFORMED ON CORRECTIVE ACTION #2; NO DEFECTS NOTED. REMOVED AND REPLACED #2 PUMP REF TTG8Q01BW3Y ON MT 773-11-00; 85% LEAK CHECK GOOD