What was found
CRACKED SUPPORT ANGLE FLOOR STRUCTURE BS 867, LBL 11 IN THE AFT CARGO BAY. REPLACED SUPPORT ANGLE LOCATED FLOOR STRUCTURE IAW SRM 51-40-02-0G-0, SRM 51-10-02-0G-0, ITEM 9, DWG 149A8102, SHEET 17 REV -, AND DWG 149A8104, SHEET 1, REV B.