What was found
CRACK INDICATION ON STUB FRAME LOCATED BETWEEN BS 294.5 TO BS 296.5 AND BTW S-8R TO S-9R AT FWD GALLEY DOOR AREA CRACK LENGTH 0.250 IN. REPLACED STUB FRAME LOCATED BS 294.5 AND BTW STR-6R TO STR-10R AT FWD GALLEY DOOR AREA IAW SRM 51-10-02-0G-0, ITEM 9, SRM 51-40-02-0G-0, AND DWG 141A8370, SHEET 9 AND 10, REV D.