As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FLOOR SUPPORT BTW BS947.5 TO BS967 ; LBL16 AND WL208.1 AT AFT GALLEY AREA. REPLACED INTERCOSTAL AND FASTENERS LOC. FLOOR STRUCTURE BTW BS947.5 TO BS967 ; LBL16 AND WL208.1 AT AFT GALLEY AREA IAW SRM 51-40-02-0G-0; SRM 51-10-02-0G-0 PARAGRAPH 9 AND DWG 147A5650 SHEET: 55; REV: A.