What was found
CRACKED FITTING LOCATED FLOOR STRUCTURE BS947 AND LBL10. REPLACED FITTING LOCATED FLOOR STRUCTURE IAW SRM-51-10-02, ITEM (9), SRM-51-40-02, AND DWG:149A8103, SHEET 7 REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED FITTING LOCATED FLOOR STRUCTURE BS947 AND LBL10. REPLACED FITTING LOCATED FLOOR STRUCTURE IAW SRM-51-10-02, ITEM (9), SRM-51-40-02, AND DWG:149A8103, SHEET 7 REV A.