What was found
BS 663 VAPOR BARRIER ATTACH ANGLE HAS CRACK AT RBL 9. REMOVED VAPOR BARRIER ATTACH ANGLE AT BS633, RBL 9 IAW SRM 51-40-02. LOCATED AND MATCH DRILLED NEW RT BS 663 VAPOR BARRIER ATTACH ANGLE IAW SRM 51-40-06. PERFORMED NDT PER PART 6; 51-00-00 PROCEDURE 16 OF HOLES COMMON TO REPAIR; IN TANK HOLES AND WEB HOLES. INSTALLED FASTENERS COMMON TO FUEL TANK IAW SRM 51-40-02