What was found
CRACKED FITTING LOCATED BS 947.5 AT LEVEL STR 26L AT AFT CARGO BAY REPLACED THE FITTING IAW SRM 51-40-02 SRM 51-10-02 AND DWG 149A8103 SHEET 8 REV-.MEASURE OF CRACK IS L=1.072.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED FITTING LOCATED BS 947.5 AT LEVEL STR 26L AT AFT CARGO BAY REPLACED THE FITTING IAW SRM 51-40-02 SRM 51-10-02 AND DWG 149A8103 SHEET 8 REV-.MEASURE OF CRACK IS L=1.072.