FSD STUB FRAME IS CRACKED AT BS 296; BETWEEN STR 8 AND 9 RT; CRACK IS 0.6' LONG LOCATED IN THE FRAME JOGGLE AREA LOCATED ABOVE THE TOP END OF THE SEAL DEPRESSOR; CONTACT ENGINEERING VIA THE TSR POLICY NOTE THE CRACK WAS FOUND USING HFEC. REMOVED AND REPLACED FSD STUB FRAME IAW SRM 51-40-02-0G-0, AND DWG 141A8370 REV D.