What was found
FUSELAGE HAS A .45 VERTICAL CRACK AT BS 727A; APPROX. 3 ABOVE STR 14R; VERIFIED WITH HFEC PER NDT PART 6; 51-00-00 PROCEDURE 23 AND FLUORESCENT PENETRANT INSPECTION PER SOPM 20-20-02. .26-153-01210
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE HAS A .45 VERTICAL CRACK AT BS 727A; APPROX. 3 ABOVE STR 14R; VERIFIED WITH HFEC PER NDT PART 6; 51-00-00 PROCEDURE 23 AND FLUORESCENT PENETRANT INSPECTION PER SOPM 20-20-02. .26-153-01210